FEI/4/hwIfInputUnucFlowThresholdAlarm_active: Unknown unicast flow is beyond the alarm threshold.(entPhysicalName = [hwUNUCPortName],hwIfUnknownUnicastRealFlow = [hwUNUCPortRealFlow],hwIfUnknownUnicastAlarmThreshold=[hwUNUCPortAlarmThreshold])
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
hwUNUCPortName |
Name of the interface. |
hwUNUCPortRealFlow |
Percentage of the unknown unicast traffic volume to the interface traffic volume. |
hwUNUCPortAlarmThreshold |
Alarm threshold. |
1. Run the display this command in the interface view to check the VLAN or VSI configured on the interface.
2. Enter the corresponding VLAN or VSI view from the system view, and run the display this command to check whether MAC address learning has been enabled.
3. Run the undo mac-address learning disable command to enable MAC address learning. Then check whether the alarm has been cleared.
4. Collect alarm, log, and configuration information, and contact technical support personnel.
5. End.