L2VPN/2/hwKompellaVcDown_active

Message

L2VPN/2/hwKompellaVcDown_active: The status of the Kompella VC turned DOWN. (VcVpnName=[VcVpnName], CeId=[CeId], InterfaceIndex=[InterfaceIndex], RemoteCeId=[RemoteCeId], SecondaryVc=[SecondaryVc], HWL2VpnStateChangeReason=[HWL2VpnStateChangeReason], PeerAddress=[PeerAddress], TunnelPolicyName=[TunnelPolicyIndex], ActiveState=[ActiveState])

Description

A BGP VC went Down.

Parameters

Parameter Name Parameter Meaning

VcVpnName

MPLS L2VPN instance name

CeId

ID of the local CE

InterfaceIndex

Index of an AC interface

RemoteCeId

ID of the remote CE

SecondaryVc

Secondary VC

HWL2VpnStateChangeReason

Reason of the VC status change

PeerAddress

Peer IP address of the PW

TunnelPolicyIndex

Name of the tunnel policy used by the PW

ActiveState

PW forwarding status

Possible Causes

  • Cause 1: Invalid reason type.
  • Cause 3: Local VC Deleted.
  • Cause 24: Tunnel was Down.
  • Cause 43: BFD for pw status changed to Down.
  • Cause 47: Manual set was enabled.
  • Cause 94: PW or AC token exceed.

Procedure

  • Cause 1: Invalid reason type.

    1. Collect alarm information and configuration information, and then contact technical support personnel.

    2. End.

  • Cause 3: Local VC Deleted.

    1. Check whether the VPWS connection needs to be deleted.

    • If the VPWS connection needs to be deleted, go to Step 4.
    • If the VPWS connection does not need to be deleted, go to Step 2.

    2. Run the connection command to re-establish the VPWS connection. Then, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.
    • If the alarm persists, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

    4. End.

  • Cause 24: Tunnel was Down.

    1. Run the display mpls l2vpn connection interface interface-type interface-number command to check whether the PW has a tunnel ID.

    • If the tunnel ID exists, go to Step 3.
    • If the tunnel ID does not exist, go to Step 2.

    2. Check whether the public network interface is Down. If it is Down, bring it Up and then run the display tunnel-info all command to check the tunnel status. After the tunnel goes Up, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.
    • If the alarm persists, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

    4. End.

  • Cause 43: BFD for pw status changed to Down.

    1. Perform the troubleshooting operations described in hwBfdSessDown to rectify the fault. Then, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 3.
    • If the alarm persists, go to Step 2.

    2. Collect alarm information and configuration information, and then contact technical support personnel.

    3. End.

  • Cause 47: Manual set was enabled.

    1. Run the display this command on the AC interface to check whether the manual-set pw-ac-fault configuration exists.

    • If the configuration exists, go to Step 2.
    • If the configuration does not exist, go to Step 3.

    2. Run the undo manual-set pw-ac-fault command to delete the configuration and then check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.
    • If the alarm persists, go to Step 3.

    3. Collect alarm information and configuration information, and then contact technical support personnel.

    4. End.

  • Cause 94: PW or AC token exceed.

    1. Collect alarm information and configuration information, and then contact technical support personnel.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
Next topic >