TUNNEL-TE/2/hwMplsApsDegraded_clear

Message

TUNNEL-TE/2/hwMplsApsDegraded_clear: The APS degraded alarm received by the tunnel protection group is cleared.(IfIndex=[WorkTunnelIfIndex], SessionTunnelId=[SessionTunnelId], LocalLspId=[LocalLspId], IngressLsrId=[IngressLsrId], EgressLsrId=[EgressLsrId],WorkTunnel=[WorkTunnel], SignalingProtocol=[SgnlPrtcl], SignalledTunnelName=[SignalledTunnelName])

Parameters

Parameter Name Parameter Meaning

WorkTunnelIfIndex

Work Tunnel Interface Index

SessionTunnelId

Tunnel ID of a session

LocalLspId

LSP ID of a tunnel session

IngressLsrId

LSR ID of the ingress of a tunnel

EgressLsrId

LSR ID of the egress of a tunnel

WorkTunnel

Name of the working tunnel in a tunnel protection group

SgnlPrtcl

Signaling protocol used by a tunnel session including:

  • 1: RSVP
  • 2: STATIC
  • 3: CRSTATIC

SignalledTunnelName

Tunnel alias.

Possible Causes

The APS degraded alarm received by the tunnel protection group is cleared.

Procedure

1. This trap message is informational only, and no action is required.