PIC/1/hwOpticalFail_active-135947

Message

PIC/1/hwOpticalFail_active: The optical module failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=135947, ReasonDescription=The Smart-Clock module frequency lock state is failed.)

In VS mode, this log is supported only by the admin VS.

Description

The optical module failed partially.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Index of the physical entity.

EntPhysicalIndex

Index of the physical entity.

EntPhysicalName

Name of the physical entity.

EntityTrapFaultID

Error code.

ReasonDescription

Indicates the description of the possible cause.

Possible Causes

The Smart-Clock module frequency lock state is failed.

Procedure

1. Adjust the GPS antenna. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm is not cleared, go to Step 2.

2. Replace the antenna system. Then, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm is not cleared, go to Step 2.

3. Collect alarm information, log information and configuration information, and then contact technical support personnel.

4. End.