DEVM/1/hwPowerFail_active-136707

Message

DEVM/1/hwPowerFail_active: A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136707, Reason=The power module failed.)

In VS mode, this log is supported only by the admin VS.

Description

The power supply experienced a partial failure, which may be caused by a component failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

Possible Causes

The power module failed.

Procedure

1. Run the display device slot-id command in the user view to view information about the faulty power supply module. Check whether all components are in PRESENT state and all the Status items are normal.

2. Replace the faulty components or the power supply module.

3. If the alarm persists, collect trap, log, and configuration information, and contact technical support.

4. End.