DEVM/1/hwPowerFail_active: A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136708, Reason=EEPROM on the power module failed.)
In VS mode, this log is supported only by the admin VS.
The power supply experienced a partial failure, which may be caused by a component failure.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
1. If a board is powered off because of insufficient power supply, replace the power supply module.
2. If the alarm persists, collect trap, log, and configuration information, and contact technical support.
3. End.