DEVM/1/hwPowerFail_active-136988

Message

DEVM/1/hwPowerFail_active: A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136988, Reason=The app of the power module is abnormal.)

In VS mode, this log is supported only by the admin VS.

Description

The power supply experienced a partial failure, which may be caused by a component failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

Possible Causes

The app of the power module is abnormal.

Procedure

1. Upgrade the PM module.

2. Upgrade end and check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 3.

3. Replace the power module.

Power off the faulty power module before replacing it.

Then check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 5.
  • If the alarm persists, go to Step 4.

4. Collect trap, log, and configuration information, and contact technical support.

5. End.

Copyright © Huawei Technologies Co., Ltd.