DEVM/1/hwPowerInvalid_active: A power module experienced a complete failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136964, Reason=Over-temperature occurred on the power module.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
1. Check ventilation on the router and in the equipment room. If the ventilation conditions are normal, go to Step 2.
2. Check whether the power supply module is normal. - If so, go to Step 3.
3. Replace the power supply module.
4. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.
5. End.