DEVM/1/hwPowerInvalid_active-136963

Message

DEVM/1/hwPowerInvalid_active: A power module experienced a complete failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136963, Reason=Under-input-voltage occurred on the power module.)

In VS mode, this log is supported only by the admin VS.

Description

Power invalid.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

Possible Causes

Under-input-voltage occurred on the power module.

Procedure

1. Check whether external power supply is normal. - If so, go to Step 2.

2. Replace the power supply module. If the alarm persists, collect alarm information, log information and configuration information, and then contact technical support personnel.

3. End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >