DEVM/1/hwPowerInvalid_active: A power module experienced a complete failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136982, Reason=The power type does not match the type of the backplane.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
1. Check whether the power module and backplane types match. If they do not match, replace the power module with one matching the backplane type and then check whether the trap is cleared.
2. Collect trap, log, and configuration information, and contact technical support personnel.
3. End.