DEVM/1/hwPowerInvalid_active-136986

Message

DEVM/1/hwPowerInvalid_active: A power module experienced a complete failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136986, Reason=The A plane power supply on the power module is faulty.)

In VS mode, this log is supported only by the admin VS.

Description

Power invalid.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

Possible Causes

The A plane power supply on the power module is faulty.

Procedure

1. Check external power is normal or not.

  • If abnormal, go 2.
  • If normal, go 3.

2. Repair external power circuit.

  • If normal go 5.
  • If abnormal go 3.

3. Change pm module.

  • If normal, go 5.
  • If abnormal, go 4.

4. Collect alarm information, log information and configuration information, and then contact technical support personnel.

5. End.