SYSTEM/2/hwSystemConfigError_clear

Message

SYSTEM/2/hwSystemConfigError_clear: The system configuration error has been rectified. ( EntityTrapFaultID = [EntityTrapFaultID])

In VS mode, this log is supported only by the admin VS.

Parameters

Parameter Name Parameter Meaning

EntityTrapFaultID

Trap error code:

  • 144128: The PAF version is inconsistent with the version of the startup software package.
  • 144129: The boards and subcards of the device are not inserted into the corresponding slots.
  • 144130: The versions of the active and standby main control boards are inconsistent.
  • 144133: The memory of the active main control board is inconsistent with that of the standby main control board.
  • 144134: The PTN startup mode does not match the mode selected during license activation.

Possible Causes

  • Cause 1:A system configuration error was rectified.
  • Cause 144128:The fault was rectified when the version in the PAF file is inconsistent with that of the startup software package.
  • Cause 144129:The fault was rectified when the boards and subcards were installed in incorrect slots.
  • Cause 144130:The fault was rectified when the software versions on the master and slave control boards are inconsistent.
  • Cause 144133:The fault was rectified when the memory size of the system master main control board was inconsistent with that of the system slave main control board.
  • Cause 144134:The fault was rectified when the PTN start mode is inconsistent with that defined in the activated license.

Procedure

This alarm message is informational only, and no action is required.