DEVM/4/hwUnstableAlarm_active: The physical entity was installed unstably. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=[143362], Reason=The fan was installed unstably.)
In VS mode, this log is supported only by the admin VS.
A physical entity, such as a board, a power module, or a fan module, was installed improperly.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The index for this entry. |
EntityTrapEntType |
The textual name of the physical entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
Reason |
Reason. |
EntPhysicalIndex |
Physical Index. |
1.Check if the fan is properly installed, if pins have bent, and if the fan connectors become faulty.
2.If the fan is not properly installed, re-install it.
3.If the pins on the backplane have bent, do not install a new fan into the faulty slot. Collect the information about alarms, logs, and configurations, and then contact technical support personnel.
4.If only the fan connectors are found faulty, replace the fan with a new one.
5.If services on the fan are abnormal, collect the information about alarms, logs, and configurations, and then contact technical support personnel.
6.End.