DEVM/4/hwUnstableAlarm_active-143362

Message

DEVM/4/hwUnstableAlarm_active: The physical entity was installed unstably. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=[143362], Reason=The fan was installed unstably.)

In VS mode, this log is supported only by the admin VS.

Description

A physical entity, such as a board, a power module, or a fan module, was installed improperly.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalName

The index for this entry.

EntityTrapEntType

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

EntPhysicalIndex

Physical Index.

Possible Causes

The fan was installed unstably.

Procedure

1.Check if the fan is properly installed, if pins have bent, and if the fan connectors become faulty.

2.If the fan is not properly installed, re-install it.

3.If the pins on the backplane have bent, do not install a new fan into the faulty slot. Collect the information about alarms, logs, and configurations, and then contact technical support personnel.

4.If only the fan connectors are found faulty, replace the fan with a new one.

5.If services on the fan are abnormal, collect the information about alarms, logs, and configurations, and then contact technical support personnel.

6.End.

Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.