The table contains attribute of TLPs.
The indexes of the table are hwIpfpmDcpInstId, hwIpfpmDcpTlpId.
OID |
Object |
Syntax |
Max Access |
Description |
Implemented Specifications |
---|---|---|---|---|---|
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.1 |
hwIpfpmDcpInstTlpRole |
INTEGER{in-point(1),out-point(2),mid-point(3)} |
read-create |
The object indicates the TLP position 'in-point(1)' or 'out-point(2) or 'mid-point(3)'. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.2 |
hwIpfpmDcpInstTlpFlowType |
INTEGER{null(0),forward(1),backward(2),bidirectional(3),forwardandbackward(4)} |
read-create |
The object indicates the flow type of the instance TLP is 'forward(1)' or 'backward(2)' or 'bidirectional(3)' or 'forwardandbackward(4)'. Only 'forward(1)' and 'backward(2)' can be configured when 'hwIpfpmDcpInstTlpRole' is 'mid-point(3)'. The value 'null(0)' represents that this flow is not configured under the instance. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.3 |
hwIpfpmDcpInstTlpDirec |
INTEGER{ingress(1),egress(2)} |
read-create |
The object indicates the TLP is 'ingress(1)' or 'egress(2)' of the flow of DCP test instance. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.4 |
hwIpfpmDcpInstTlpVpnLabel |
Integer32{(-1,1048575)} |
read-create |
The VPN label of of the flow that the TLP measured. The value -1 represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.5 |
hwIpfpmDcpInstTlpCtrlWordFlag |
INTEGER{true(1),false(2)} |
read-create |
The control word flag of the flow that the TLP measured. The value false(2) represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.6 |
hwIpfpmDcpInstTlpLspLabel |
Integer32{(-1,1048575)} |
read-create |
The LSP label of the flow that the TLP measured. The value -1 represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.7 |
hwIpfpmDcpInstTlpL2VpnFlag |
INTEGER{true(1),false(2)} |
read-create |
The L2VPN flag of the flow that the TLP measured. The value false(2) represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.8 |
hwIpfpmDcpInstTlpTpId |
OCTET STRING{(3,4)} |
read-create |
The tpid for vlan. The value range is from '600' to 'FFFF'. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.9 |
hwIpfpmDcpInstTlpRowStatus |
INTEGER{active(1),notInService(2),notReady(3),createAndGo(4),createAndWait(5),destroy(6)} |
read-create |
Used for controlling the creation and deletion of this row. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.10 |
hwIpfpmDcpInstTlpMultiSrcType |
INTEGER{master(0),slave(1)} |
read-create |
The object indicates the type of multicastsrc 'master(0)'or 'slave(1)'. |
The actually supported value range is 0. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.11 |
hwIpfpmDcpInstTlpFlowLabelFlag |
INTEGER{true(1),false(2)} |
read-create |
This value indicate whether the flow-label is configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.12 |
hwIpfpmDcpInstTlpLspLabel2 |
Integer32{(-2,1048575)} |
read-create |
The LSP label of the flow that the TLP measured. The value -1 represents that this object is not configured. The value -2 represents that this object matches any label. |
The actually supported value range is -2-1048575. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.16 |
hwIpfpmDcpInstTlpBackwardVpnLabel |
Integer32{(-1,1048575)} |
read-create |
The VPN label of of the flow that the TLP measured. The value -1 represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.17 |
hwIpfpmDcpInstTlpBackwardCtrlWordFlag |
INTEGER{true(1),false(2)} |
read-create |
The control word flag of the flow that the TLP measured. The value false(2) represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.18 |
hwIpfpmDcpInstTlpBackwardLspLabel |
Integer32{(-1,1048575)} |
read-create |
The LSP label of the flow that the TLP measured. The value -1 represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.19 |
hwIpfpmDcpInstTlpBackwardLspLabel2 |
Integer32{(-2,1048575)} |
read-create |
The LSP label of the flow that the TLP measured. The value -1 represents that this object is not configured. The value -2 represents that this object matches any label. |
The actually supported value range is -2-1048575. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.21 |
hwIpfpmDcpInstTlpBackwardL2VpnFlag |
INTEGER{true(1),false(2)} |
read-create |
The L2VPN flag of the flow that the TLP measured. The value false(2) represents that this object is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.22 |
hwIpfpmDcpInstTlpBackwardFlowLabelFlag |
INTEGER{true(1),false(2)} |
read-create |
This object indicates whether the flow label function is configured for the backward target flow. If the value is false(2), the flow label function is not configured. |
This object is implemented as defined in the corresponding MIB files. |
1.3.6.1.4.1.2011.5.25.316.2.1.11.1.25 |
hwIpfpmDcpInstTlpBackwardTpId |
OCTET STRING{(3,4)} |
read-create |
The tpid for vlan. The value range is from '600' to 'FFFF'. |
This object is implemented as defined in the corresponding MIB files. |