(Optional) Configuring an Alarm Threshold for the Outbound Bandwidth Usage of the Soft Pipe

After the hard pipe is configured on the network-side or AC-side interface, you can configure an alarm threshold for the soft pipe bandwidth usage to monitor the soft pipe load on the device. When the bandwidth usage exceeds the pre-warning or alarm threshold, the device reports an alarm to prompt users to properly plan service traffic or expand the device capacity. You can set the alarm threshold and clear alarm threshold as required.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface { ethernet | gigabitethernet }

    The specified Ethernet interface view is displayed.

  3. Run qos soft-pipe trap-threshold output-rate bandwidth-in-use [ resume-rate resume-threshold ]

    The alarm and clear alarm thresholds are set for the outbound bandwidth usage of the soft pipe.