Feature Requirements |
Series |
Models |
---|---|---|
1. Multiple VSs are supported. However, color-flag (coloring) can be configured only in the admin VS and is shared by all VSs. If the coloring bit conflicts with QoS and needs to be modified, the IP FPM function in VSn needs to use the coloring configuration of the admin VS. (1) color-flagloss-measure{tos-bit<bit>|flags-bit0}delay-measure{tos-bit<bit>|flags-bit0}; (2) color-flagloss-measure{tos-bit<bit>|flags-bit0}delay-measurenone; (3)undocolor-flag 2. Only the instance statistics in the admin VS can be sent to the PM, and the instance performance statistics in VSn cannot be sent to the PM. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
BRAS services do not support multiple VSs (BRAS services can be deployed only in the admin VS). |
NetEngine 8000 F |
NetEngine 8000 F1A |
cpu-defend-policy needs to be configured in the slot view. Many security functions, including CPCAR, attack source tracing, TCP/IP attack defense, application layer association, GTSM, and MA-defend, can be configured only in the admin VS and take effect in all VSs. An MA-defend policy can be configured only in the admin VS. An MA-defend policy can be configured based on a device, a board, or an interface. A device-or board-based MA-defend policy can be applied only to the admin VS. An interface-based MA-defend policy can be applied to VSn. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
FlexE logical interfaces can be created only in the admin VS. |
NetEngine 8000 F |
NetEngine 8000 F2A |
A FlexE physical interface cannot be added to VSn. |
NetEngine 8000 F |
NetEngine 8000 F2A |
The group-mac of L2PT and BPDU tunnels can be configured only in the admin VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
RADIUS services do not support multiple VSs. (RADIUS services can be deployed only in the admin VS.) |
NetEngine 8000 F |
NetEngine 8000 F1A |
The destination IP address or UDP port number cannot be configured for the output NetStream flows in the view of a non-admin-VS. The NetStream service processing board cannot be configured for an interface board in the view of a non-admin-VS. |
NetEngine 8000 F |
NetEngine 8000 F1A |
The SOC (including the command in the SOC view) can be configured only in the admin VS and takes effect in all VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
A standard Ethernet interface that has been added to VSn cannot be switched to the FlexE mode. |
NetEngine 8000 F |
NetEngine 8000 F2A |
After a standard Ethernet interface is added to VSn, the interface rate does not support auto-negotiation against an optical module. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Layer 2 loop detection commands can be configured only in the admin VS and take effect in all VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Layer 3 loop detection can be configured only in the admin VS and takes effect in all VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
After a 100GE interface before splitting or a 10GE interface after splitting is added to a VS (non-admin VS), the interface does not support splitting switching. Splitting switching can be configured after the interface is removed from the VS. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Clock services (including synchronous Ethernet, 1588v2, and NTP) can be deployed only in the admin VS. The clock service function does not take effect in VSn. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
After invalid ARP packet filtering or ARP destination address detection is configured on a main interface, the corresponding configuration is also delivered to sub-interfaces in different VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
When main interfaces and sub-interfaces are deployed in different VSs, ESI route negotiation is not supported on interfaces. Properly plan the configuration to prevent main interfaces and sub-interfaces from being deployed across VSs. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
The performance alarm and flow creation rate control on the forwarding plane are based on the board level and do not support the VS granularity. |
NetEngine 8000 F |
NetEngine 8000 F2A/NetEngine 8000 F1A |
Multicast NAT does not support multiple VSs. Plan services properly. |
NetEngine 8000 F |
NetEngine 8000 F1A |