Configuring Two-way Frame Delay Measurement in BD EVPN Networking

In BD EVPN networking, if the clocks of the MEPs at both ends of a link are not synchronized and the requirement for delay measurement is not high, two-way frame delay measurement can be configured for the link.

Context

Two-way frame delay measurement in BD EVPN networking can be either on-demand or proactive. On-demand two-way frame delay measurement is manually initiated for diagnosis of the frame transmission delay in a limited time. It can be singular or periodic measurement. Proactive two-way frame delay measurement is carried out continuously to permit proactive reporting of frame transmission delays or performance results.
  • To implement singular or periodic two-way frame delay measurement for an AC, configure on-demand two-way frame delay measurement in BD EVPN networking.

  • To implement continual two-way frame delay measurement for an AC, configure proactive two-way frame delay measurement in BD EVPN mode networking.

Procedure

  • Configure on-demand two-way frame delay measurement for an AC.

    1. Perform the following steps on the devices at both ends of an AC where on-demand two-way frame delay measurement will be implemented

      1. Run system-view

        The system view is displayed.

      2. Run cfm md md-name

        The MD view is displayed.

      3. Run ma ma-name

        The MA view is displayed.

      4. Perform the following steps on the devices where the MEPs reside:

        • On the CE, run map vlan vlan-id

          The MA is bound to a VLAN.

        • On the PE, run mapbridge-domainbd-id

          The MA is bound to a specified BD.

      5. Run mep mep-id

        The MEP is configured.

      6. Run remote-mep mep-id mep-id

        The remote MEP ID is configured.

      7. Run mep ccm-send enable

        The CCM transmission function is enabled.

      8. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The CCM reception function is enabled.

    2. Configure a test instance.

      1. To configure a test instance on the receiving device on an AC where on-demand two-way frame delay measurement will be implemented, run the test-idtest-id [ testid-file ]mep mep-id [ 8021p 8021p-value ] [ descriptiondescription ] command.

      2. To configure a test instance on the transmitting device on an AC where two-way frame delay measurement will be implemented, run the test-idtest-id [ testid-file ]mepmep-id [ macmac-address | remote-mepmep-id ] [ 8021p8021p-value ] [ descriptiondescription ] command.

    3. On the receiving device on an AC where on-demand two-way frame delay measurement will be implemented, run delay-measure two-way receivetest-idtest-id

      The DMM reception function is configured on the device.

    4. On the transmitting device on an AC where on-demand two-way frame delay measurement will be implemented, run delay-measure two-way send test-id test-id-value interval { 1000 | 10000 } count count-value

      On-demand two-way frame delay measurement is configured for an AC.

    5. Run commit

      The configuration is committed.

  • Configure proactive two-way frame delay measurement for an AC.

    1. Perform the following steps on the devices at both ends of an AC where proactive two-way frame delay measurement will be implemented:

      1. Run system-view

        The system view is displayed.

      2. (Optional) Run y1731 pm-mode enable

        Performance management (PM) to manage Y.1731 proactive performance statistics is enabled. PM saves the statistics to generated statistics files and then sends the files to the NMS.

      3. Run cfm md md-name

        The MD view is displayed.

      4. Run ma ma-name

        The MA view is displayed.

      5. Run map bridge-domain bd-id

        The MA is bound to a BD.

      6. Run mep mep-id

        The MEP is configured.

      7. Run remote-mep mep-id mep-id

        The remote MEP ID is configured.

      8. Run mep ccm-send enable

        The CCM transmission function is enabled.

      9. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The CCM reception function is enabled.

      10. (Optional) Run delay-measure two-way delay-thresholdmep mep-id upper-limit upper-limit lower-limit lower-limit [ 8021p 8021p-value ]

        Delay thresholds are configured for proactive two-way frame delay measurement based on a MEP.

      11. (Optional) Run delay-measure two-way delay-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Upper and lower thresholds are set for two-way frame delay in proactive two-way frame delay measurement based on a specified test instance.

      12. (Optional) Run delay-measure two-way variation-threshold mep mep-id upper-limit upper-limit lower-limit lower-limit [ 8021p 8021p-value ]

        Upper and lower thresholds are set for two-way frame jitter in proactive two-way frame delay measurement based on a specified MEP.

      13. (Optional) Run delay-measure two-way variation-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Upper and lower thresholds are set for two-way frame jitter in proactive two-way frame delay measurement based on a specified test instance.

    2. Configure a test instance for an AC.

      1. To configure a test instance on the receiving device on an AC where on-demand two-way frame delay measurement will be implemented, run the test-idtest-id [ testid-file ]mep mep-id [ 8021p 8021p-value ] [ descriptiondescription ] command.

      2. To configure a test instance on the transmitting device on an AC where two-way frame delay measurement will be implemented, run the test-idtest-id [ testid-file ]mepmep-id [ macmac-address | remote-mepmep-id ] [ 8021p8021p-value ] [ descriptiondescription ] command.

    3. On the receiving device on an AC where two-way frame delay measurement will be implemented, run delay-measure two-way receivetest-idtest-id

      The DMM reception function is configured on the device.

    4. On the transmitting device on an AC where two-way frame delay measurement will be implemented, run delay-measure two-way continual sendtest-id test-id-value interval interval-value [ period period ]

      On-demand two-way frame delay measurement is configured for an AC.

    5. Run commit

      The configuration is committed.

Verifying the Configuration

Run the display y1731 statistic-type twoway-delay [ test-id test-id-value ] [ count count-value ] command on the device that initiates two-way frame delay measurement to check statistics about the delay in bidirectional frame transmission.