Configuring Single-ended SLM in BD Networking

To perform packet loss performance measurement on a point-to-multipoint or multipoint-to-multipoint links, deploy single-ended synthetic loss measurement (SLM) to monitor the link quality.

Context

In BD networking, single-ended SLM includes on-demand and proactive SLM functions. On-demand single-ended SLM collects single-ended frame loss statistics at one or more specific times for diagnosis. Proactive single-ended SLM collects single-ended frame loss statistics periodically.

  • To collect performance statistics about frame loss on the network or AC side at a time or periodically, configure on-demand single-ended SLM through the BD.

  • To continuously collect performance statistics about frame loss on the AC side, configure proactive single-ended SLM through the BD.

Service packets are prioritized based on 802.1p priorities and are transmitted using different policies. Traffic from PE1 to PE3 shown in Figure 1 carries 802.1p priority values of 1 and 2. When single-ended SLM is performed for the link between PE1 and PE3, SLM frames with different priorities can be sent to determine the impact of a physical link on loss of packets with different priority values. The network administrator then can adjust QoS policies on the path. To collect accurate performance statistics, configure 802.1p priority-based single-ended SLM for the BD.

Figure 1 Networking of single-ended SLM

Procedure

  • Configure on-demand single-ended SLM.

    Configure on-demand single-ended SLM on the AC side.

    1. Perform the following steps on the devices at both ends of an AC where on-demand single-ended SLM will be implemented:

      1. Run system-view

        The system view is displayed.

      2. Run cfm mdmd-name

        The MD view is displayed.

      3. Run mama-name

        The MA view is displayed.

      4. Perform the following steps on the devices where the MEPs reside:

        • On the CE, run map vlan vlan-id

          The MA is bound to a VLAN.

        • On the PE, run map bridge-domain bd-id

          The MA is bound to a BD.

      5. Run mep mep-id interface interface-type interface-number inward

        A MEP is configured.

      6. Run remote-mep mep-id mep-id

        An RMEP is configured.

      7. Run mep ccm-send enable

        The CCM transmission function is enabled.

      8. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The CCM reception function is enabled.

      9. Run test-id test-id [ testid-file ]mep mep-id [ description description ]

        The test instance is configured on the device.

    2. Perform the following configuration on the RMEP that receives SLM frames on the AC side:

      Run loss-measure single-ended-synthetic receive test-id test-id [ time-out timeout-value ]

      The RMEP is enabled to receive SLM frames.

    3. Perform the following configuration on the MEP that sends SLM frames to initiate on-demand single-ended SLM on the AC side:

      Run loss-measure single-ended-synthetic sendtest-id test-id interval { 100 | 1000 } [ sending-count count-value ] [ time-out time-out-value ]

      On-demand single-ended SLM is configured for an AC.

    4. Run commit

      The configuration is committed.

  • Configure proactive single-ended SLM on the AC side.

    1. Perform the following steps on the devices at both ends of an AC where proactive single-ended SLM will be implemented:

      1. Run system-view

        The system view is displayed.

      2. (Optional) Run y1731 pm-mode enable

        PM is enabled to manage Y.1731 proactive performance statistics.

      3. Run cfm md md-name

        The MD view is displayed.

      4. Run ma ma-name

        The MA view is displayed.

      5. Run map bridge-domain bd-id

        The MA is bound to a BD.

      6. Run mep mep-id interface interface-type interface-number inward

        An interface-based MEP is configured.

      7. Run remote-mep mep-id mep-id

        An RMEP is configured.

      8. Run mep ccm-send enable

        The CCM transmission function is enabled.

        This command can be configured only on an interface-based MEP.

      9. Run remote-mep ccm-receive [ mep-id mep-id ] enable

        The CCM reception function is enabled.

      10. Run test-i d test-id [ testid-file ]mep mep-id [ description description ]

        The test instance is configured on the device.

      11. (Optional) Run loss-measure single-ended-synthetic local-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Upper and lower thresholds are set for the near-end frame loss rate in proactive single-ended frame loss measurement based on a specified test instance.

      12. (Optional) Run loss-measure single-ended-synthetic remote-ratio-threshold test-id test-id-value upper-limit upper-limit lower-limit lower-limit

        Upper and lower thresholds are set for the far-end frame loss rate in proactive single-ended frame loss measurement based on a specified test instance.

    2. Perform the following configuration on the RMEP that receives SLM frames on the AC side:

      Run loss-measure single-ended-synthetic receive test-id test-id [ time-out timeout-value ]

      The RMEP is enabled to receive SLM frames.

    3. Perform the following configuration on the MEP that sends SLM frames to initiate proactive single-ended SLM on the AC side:

      Run loss-measure single-ended-synthetic continual send test-id test-id interval { 1000 | 10000 } [ sending-count count-value ] [ time-out timeout ] [ period period ]

      Proactive single-ended SLM is enabled on the network or AC side.

    4. Run commit

      The configuration is committed.

Verifying the Configuration

After configuring single-ended SLM, run the display y1731 statistic-type single-synthetic-loss test-id test-id [ count count ] command on the MEP that has been enabled to send SLM frames.