This section describes how to configure one- and two-way frame delay measurement (DM) to collect reliability statistics for MPLS-TP services.
If the clocks of the two MEPs are synchronized, one-way frame DM can be conducted; otherwise, only two-way frame delay variation can be measured.
Item |
One-Way Frame DM |
Two-Way Frame DM |
---|---|---|
Statistics display |
Statistics about one-way frame DM can be displayed using the display mpls-tp oam meg meg-name statistic-type delay-measure one-way command on an RMEP. |
Statistics can be displayed using either of the following commands on a MEP:
|
Monitoring scenario |
On-demand monitoring Proactive monitoring |
On-demand monitoring Proactive monitoring |
All the steps must be performed on both the MEP and RMEP unless otherwise specified.
The system view is displayed.
A MEG is created, and the MEG view is displayed.
Configure one-way frame DM. Run any of the following commands:
Run delay-measure one-way [ interval interval-value | count count-value | exp exp-value ] *
One-way on-demand frame DM is enabled.
Run either of the following commands to view statistics about one-way on-demand frame DM as needed:
On the MEP, run delay-measure one-way proactive [ interval interval-value | exp exp-value ] *
One-way proactive frame DM is enabled.
On the RMEP, run delay-measure one-way proactive receive enable
The receive function is enabled for one-way proactive frame DM.
Run either of the following commands to view statistics about one-way proactive frame DM as needed:
Configure two-way frame DM. Configure either two-way on-demand or proactive frame DM as follows:
To enable two-way on-demand frame DM, run the delay-measure two-way [ interval {1000|10000} | count count-value | exp exp-value | two-time-stamp ] * command.
To enable two-way proactive frame DM, run the delay-measure two-way proactive [ interval { 1000 | 10000 } | exp exp-value ] * command.