After configuring a Bridge Domain (BD), you can use CE ping to check the connectivity between a PE and a CE in an Ethernet Virtual Connection (EVC) model.
An EVC model unifies the Layer 2 bearer service model and configuration model. In an EVC model, you can use CE ping to check the link reachability between a PE and a CE in a specified BD. For details about EVCs, see HUAWEI NetEngine 8000 F Series Feature Description-Local Area Network. For configuration details, see EVC Configuration.
When using CE ping to check the link reachability between a PE and a CE, you must specify a source IP address that meets the following conditions:
To avoid this problem, do not specify a used IP address as the source IP address.
<HUAWEI> ce-ping 10.1.1.1 bd 123 source-ip 10.1.1.2 mac 00e0-fc12-5678 interval 2 count 5
Info: If the designated source IP address is in use, it could cause the abnormal data transmission in EVC network. Are you sure the source-ip is unused in this EVC? [Y/N]:y
Ce-ping is in process...
10.1.1.1 is used by 00e0-fc12-3456