< Home

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.21 hwAsSlotIdInvalidNotify

Description

ASMNG/3/ASSLOTIDINVALID: OID [oid] The new member of the AS has an invalid slot ID. (AS Index=[INTEGER], AS Name=[STRING], Slot Model=[STRING], Slot ID=[INTEGER])

The stack ID of the new member device in the AS stack system was larger than 4.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.21 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Slot Model Indicates the AS model.
Slot ID Indicates the stack ID.

Impact on the System

The new member device restarts repeatedly.

Possible Causes

The stack ID of the new member device in the AS stack system was larger than 4.

Procedure

  1. Run the shutdown command on the interface connected to the new member device to shut down this interface or remove the cable of this interface.
  2. After the new member device starts, run the stack slot renumber command to change the slot ID of the new member device to less than or equal to 4.

Related Information

None.