< Home

CLKMIB_1.3.6.1.4.1.2011.5.25.186.1.8.14 hwClockSourceOutputBelowThresholdResume

Description

CLKMIB/4/CLOCKSOURCEOUTPUTABOVETHRESHOLD:OID [oid] The SSM of output above threshold notification. (hwClockAttributeChassisIndex=[integer], hwClockChassisId =[integer], hwClockPllId=[integer], hwClockAttributeOutThreshold=[integer], hwClockAttributeOutValue=[integer], hwClockCurSourceName=[STRING])

The alarm generated when the frequency offset detection functioned abnormally was cleared.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.186.1.8.14 Warning environmentalAlarm(5)

Parameters

Name Meaning

[oid]

Indicates the MIB object ID of the alarm.

hwClockAttributeChassisIndex

Index of the chassis where the clock source resides. The index is always 1 for a single chassis.

hwClockChassisId

Chassis where the clock source resides.

hwClockPllId

ID of the clock source type. The value can be:

  • System(1): System PLL

  • sync2M-1(2): 2M PLL-1

  • sync2M-2(3): 2M PLL-2

hwClockAttributeOutThreshold

Lower threshold for the quality level of the clock signals output by the external clock. The value can be:
  • 2: prc;

  • 4: ssua;

  • 8: ssub;

  • 11: sec;

  • 15: dnu.

The default SSM level corresponding to the lower threshold is dnu. The SSM level can be configured as prc, sec, ssua, or ssub.

HwClockAttributeOutValue

Quality level of the clock signals output by the external clock. The value can be:
  • 2: prc;

  • 4: ssua;

  • 8: ssub;

  • 11: sec;

  • 15: dnu.

hwClockCurSourceName

Name of the current clock source

Impact on the System

None.

Possible Causes

When the SSM level of the clock signals output by the external clock is higher than the lower threshold, the alarm clearance is reported.

Procedure

  1. This alarm is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.