CLKMIB_1.3.6.1.4.1.2011.5.25.186.1.8.6 hwClockSourceOutputBelowThreshold

Description

CLKMIB/4/CLOCKSOURCEOUTPUTBELOWTHRESHOLD: OID [oid] The SSM of output below threshold notification.(hwClockAttributeChassisIndex = [integer], hwClockChassisId = [integer], hwClockPllId = [integer], hwClockAttributeOutThreshold = [integer], hwClockAttributeOutValue = [integer], hwClockCurSourceName = [STRING])

The SSM level of output clock signals was below the lower limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.186.1.8.6 Warning equipmentAlarm(5)

Parameters

Name Meaning

[oid]

Indicates the MIB object ID of the alarm.

hwClockAttributeChassisIndex

Indicates the index of the chassis where the clock source resides. The index is always 1 for a single chassis.

hwClockChassisId

Indicates the ID of the chassis where the clock source resides.

hwClockPllId

Indicates the clock source type ID.

The value can be:

  • System(1): system phase-locked loop
  • sync2M-1(2): 2M phase-locked loop-1
  • sync2M-2(3): 2M phase-locked loop-2

hwClockAttributeOutThreshold

Indicates that the lower limit of the SSM level of output clock signals.

The value of the SSM level can be:

  • 2: prc
  • 4: ssua
  • 8: ssub
  • 11: sec
  • 15: dnu

hwClockCurSourceName

Indicates the current clock source name.

Impact on the System

The output of the PLL will be blocked.

Possible Causes

  1. The lower limit to the SSM level of output clock signals was set too high.

  2. The SSM level of the signal output by the traced clock source changed.

Procedure

  1. Run the display clock config command to check the threshold of the SSM level of the output clock signal.

    • If the bits output threshold field displays dnu, no output threshold is set. Go to step 3.

    • If the bits output threshold field is displayed as another value, go to step 2.

  2. Run the display clock source command to check the output SSM level of the clock source.

    • If the output SSM level is below the threshold, run the clock source ssm command in the system view or run the clock ssm command in the interface view to change the output SSM level threshold.

    • If the output SSM level is not below the threshold, go to step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.