< Home

EMDI_MB_1.3.6.1.4.1.2011.5.25.227.2.1.59 hwEMDIIndicatorOverThresholdResume

Description

EMDI_MB/4/EMDI_TRAP_OVERTHRESHOLD_RESUME:OID [OID] The monitor indicator of the EMDI instance is lower than the threshold in 60 consecutive periods.(EmdiInstId=[INTEGER], Type=[INTEGER], Value=[INTEGER], Threshold=[INTEGER]/100000)

A monitoring indicator detected by an eMDI instance fell below the alarm threshold in 60 consecutive monitoring intervals.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.59 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
EmdiInstId Indicates the eMDI instance ID.
Type

Indicates the eMDI alarm threshold type:

  • 1: Alarm generated when the loss rate of RTP packets transported over UDP exceeds the threshold
  • 2: Alarm generated when the out-of-order rate of RTP packets transported over UDP exceeds the threshold
  • 3: Alarm generated when the loss rate of downstream TCP packets exceeds the threshold
  • 4: Alarm generated when the loss rate of upstream TCP packets exceeds the threshold
Value Indicates the value of an eMDI monitoring indicator.
Threshold Indicates the eMDI alarm threshold.

Impact on the System

None

Possible Causes

The quality of services monitored by the eMDI instance resumed.

Procedure

  • This alarm message is informational only, and no action is required.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >