ERRDOWN/4/ErrordownOccur: OID [oid] Error-down occurred. (Ifindex=[INTEGER], Ifname=[STRING], Cause=[STRING])
The alarm was generated when an errordown event occurred.
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
1.3.6.1.4.1.2011.5.25.257.2.1 |
Warning |
communicationsAlarm(2) |
Name | Meaning |
---|---|
oid |
Indicates the MIB object ID of the alarm. |
IfIndex |
Index of an interface. |
Ifname |
Interface name. |
Cause |
Cause of the errordown event. |
After the errordown event occurs, traffic cannot be forwarded on relevant interfaces and services are interrupted.
EFM detected a link fault, which can be a fault that occurred on the remote end or a threshold-crossing event.
The MSTP edge port received BPDU packets.
After the number of secure MAC addresses learned by an interface reaches the maximum value, the interface receives packets from another MAC address.
MAC address flapping occurred.
The number of CRC error packets received by the interface during the alarm interval reached the alarm threshold.
The number of link flappings during the link flapping period reached the alarm threshold.
The current optical power of the interface fell below the lower alarm threshold.
Attack packets occurred on the interface.
The number of Runts error packets received by the interface reached the alarm threshold.
Only the S5720-EI supports the alarm indicating that the number of received Runts error packets reaches the alarm threshold.
If the value of the Cause field is bpdu-protection, go to Step 2.
If the value of the error-down cause field is port-security, rectify the fault according to the log L2IFPPI_1.3.6.1.4.1.2011.5.25.315.3.2 hwPortVlanSecureMacAlarm.
If the value of the error-down cause field is mac-address-flapping, rectify the fault according to the log L2IFPPI_1.3.6.1.4.1.2011.5.25.160.3.7 hwMflpVlanAlarm.
If the value of the Cause field is efm-threshold-event, rectify the fault according to the log EFM_1.3.6.1.4.1.2011.5.25.136.1.6.4 hwDot3ahEfmThresholdEvent.
If the value of the Cause field is efm-remote-failure, rectify the fault according to the log EFM_1.3.6.1.4.1.2011.5.25.136.1.6.5 hwDot3ahEfmNonThresholdEvent.
If the value of the error-down cause field is error-statistics, rectify the fault according to the log IFNET_1.3.6.1.4.1.2011.5.25.41.4.1 hwIfMonitorCrcErrorRising.
If the value of the error-down cause field is link-flap, rectify the fault according to the section An Ethernet Interface Frequently Alternates Between Up and Down States in "Ethernet Interface Configuration" in the S2720, S5700, and S6700 V200R019C10 Configuration Guide - Interface Management.
If the value of the error-down cause field is transceiver-power-low, rectify the fault according to the log ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136194.
If the value of the error-down cause field is auto-defend, rectify the fault according to the next log.
If the value of the Cause field is runts-error-statistics, go to step 4.
Run:
interface interface-type interface-num
The interface view is displayed.
Run:
undo stp edged-port and undo shutdown
The edge port configuration is removed. Check whether the log still exists. If the log still exists, go to Step 5.