Table 1 lists the switch models supporting a 600 W AC power module.
Power Module Name |
Product Support |
---|---|
PAC600S12-CB |
S5731-H24T4XC, S5731-H48T4XC, S5731-S24T4X, S5731-S48T4X, S5731S-S24T4X-A, S5731S-S48T4X-A, S5731S-H24T4XC-A, S5731S-H48T4XC-A, S5732-H24S6Q, S5732-H48S6Q, S5731S-H24T4S-A, S5731S-H48T4S-A, S5731S-H24T4X-A, and S5731S-H48T4X-A S6730-H24X6C, S6730-H48X6C, S6730-S24X6Q, S6730S-S24X6Q-A, and S6730S-H24X6C-A |
Table 2 describes the functions of a 600 W AC power module.
Function |
Description |
|
---|---|---|
Input protection |
Input undervoltage protection |
In this protection state, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply. |
Input overcurrent protection |
In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range. |
|
Output protection |
Output overvoltage protection |
In this protection state, the power module stops supplying power intermittently. When the output voltage restores to the normal range, the power module automatically resumes power supply. |
Output overcurrent protection |
In this protection state, the power module supplies power intermittently. When the output current is within a range, the power module automatically resumes power supply. |
|
Output short-circuit protection |
In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply. |
|
Overtemperature protection |
When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply. |
|
Hot swapping |
Supported |
When a power module enters overtemperature protection state, take measures to lower the ambient temperature. The power module can automatically start supplying power again when the temperature falls within the normal range.
1. Lock |
2. Indicator |
3. Fan air vent |
4. Handle |
5. Airflow flag (air out) |
6. AC power socket |
- |
- |
Table 3 describes the indicator on a 600 W AC power module panel.
Indicator |
Color |
Description |
---|---|---|
STATUS: running status indicator |
Green |
|
Table 4 lists specifications of a 600 W AC power module.
Item |
Description |
---|---|
Dimensions (H x W x D) |
40 mm x 90 mm x 215 mm (1.6 in. x 3.5 in. x 8.5 in.) |
Weight |
0.95 kg (2.09 lb) |
Rated input voltage range |
100 V AC to 240 V AC, 50/60 Hz 240 V DC |
Maximum input voltage range |
90 V AC to 290 V AC, 45 Hz to 65 Hz 190 V DC to 290 V DC |
Maximum input current |
100 V AC to 240 V AC: 8 A 240 V DC: 4 A |
Maximum output current |
50 A |
Rated output voltage |
12 V |
Rated output power |
600 W |
Part number |
02312FFU |