< Home

POE/5/PDPOWERUPCHANGE

Message

POE/5/PDPOWERUPCHANGE: The power-up mode of the PD connected to [STRING1] has changed from [STRING2] to [STRING3].

Description

The power supply standards of the PD connected to the interface changed.

Parameters

Parameter Name Parameter Meaning

[STRING1]

Indicates the interface name.

[STRING2]

Indicates the previous power supply standards.

[STRING3]

Indicates the new power supply standards.

Possible Causes

The supply power of the switch changed.

Procedure

  1. Determine whether the power supply standards of the PD changed as expected.
    • If so, no action is required.
    • If not, go to step 2.
  2. Run the display poe power-state interface interface-type interface-number command to check whether the power auto-negotiation function has been enabled on the interface based on the PD power auto-neg state field.
    • If so, run the undo poe power auto-neg enable command to disable the power auto-negotiation function. If the supply power of the switch is insufficient, disabling the power auto-negotiation function may cause PDs to be unable to be powered on normally.
    • If not, go to step 3.
  3. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >