< Home

S5735-S8P2X-IA200G1

Version Mapping

Table 1 lists the mapping between the S5735-S8P2X-IA200G1 chassis and software versions.

Table 1 Version mapping

Series

Model

Software Version

S5730-S-I

S5735-S8P2X-IA200G1

V200R019C10 and later versions

Appearance and Structure

Figure 1 S5735-S8P2X-IA200G1 appearance
Figure 2 Interior of the S5735-S8P2X-IA200G1 maintenance compartment

1

Eight PoE+ 10/100/1000BASE-T ports

2

One USB port

3

Two 10GE SFP+ ports

Applicable modules and cables:
NOTE:

If one port uses a GPON optical module, the other port cannot be used at the same time.

4

One ETH management port

5

One console port

6

Monitoring port

  • DI: signal input line, which connects to a door status sensor.
  • DO: signal output line, which connects to a camera alarm signal cable.
NOTE:

The monitoring port can be used to detect the status of a connected external device, such as the opening and closing of the maintenance compartment door.

The monitoring port is used with a conductive cable. The minimum cross-sectional area of the conductor connected to a conductive cable is 0.3 mm2 or 22 AWG, and the maximum cross-sectional area of the conductor is 1.3 mm2 or 16 AWG.

For details about how to use a monitoring port, see "Monitoring Interface Configuration" in the Configuration Guide - Device Management Configuration.

7

220 V AC power input socket

8

Fiber management tray (FMT)

NOTE:

The FMT is optional.

9

220 V AC power input circuit breaker

NOTICE:

This circuit breaker is optional.

Connect an external power cable to the 220 V AC power input circuit breaker when it is in use.

An external power cable needs to be prepared onsite. Ensure that the wires of the external cable are correctly connected to the L and N sockets of a plug.

The circuit breaker supports a maximum of 32 A input current and provides two 220 V AC outputs.

  • One output is connected to the AC power input socket of the switch to supply power to the switch.
  • The other output is connected to the 220 V AC power output circuit breaker of the switch to supply power to connected PDs (such as strobe lights and non-PoE PTZ dome cameras).

10

220 V AC power output circuit breaker

NOTICE:

This circuit breaker is optional.

The 220 V AC power output circuit breaker provides overcurrent protection only, and is only used for external power conversion. It supports a maximum of 10 A output current.

The connected external devices need to provide certain surge protection capabilities. It is recommended that the surge protection capabilities for both differential and common modes be 20 kA.

11

12 V DC power output socket

NOTE:

The switch provides five 12 V DC outputs to external devices, such as strobe lights and non-PoE PTZ dome cameras.

12

24 V AC power output socket

NOTE:

The switch provides two 24 V AC outputs to external devices, such as strobe lights and non-PoE PTZ dome cameras.

13

PE cable ground terminal

NOTE:

It is used to ground a PE power cable for 220 V AC input or output.

14

Door status sensor

NOTE:

It reports an alarm when the maintenance compartment door of the switch is opened.

15

Ground screw

NOTE:

It is used to ground the switch. The ground cable needs to be purchased separately.

16

Cable outlet

Port Description

10/100/1000BASE-T port

A 10/100/1000BASE-T Ethernet electrical port sends and receives service data at 10/100/1000 Mbit/s, and must use an Ethernet cable. Table 2 describes the attributes of a 10/100/1000BASE-T Ethernet electrical port.
Table 2 Attributes of a 10/100/1000BASE-T Ethernet electrical port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3, IEEE802.3u, IEEE802.3ab

Working mode

10/100/1000 Mbit/s auto-sensing

Maximum transmission distance

100 m

10GE SFP+ port

A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 3 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 3 Attributes of a 10GE SFP+ port

Attribute

Description

Connector type

LC/PC

Optical port attributes

Depend on the optical module used

Standards compliance

IEEE802.3ae

Working mode

GE/10GE auto-sensing

Console port

The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4.
Table 4 Attributes of a console port

Attribute

Description

Connector type

RJ45

Standards compliance

RS-232

Working mode

Duplex Universal Asynchronous Receiver/Transmitter (UART)

Baud rate

9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s

Default value: 9600 bit/s

ETH management port

You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. Table 5 describes the attributes of an ETH management port.
Table 5 Attributes of an ETH management port

Attribute

Description

Connector type

RJ45

Standards compliance

IEEE802.3

Working mode

10/100 Mbit/s auto-sensing

Maximum transmission distance

100 m

USB port

The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.

USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicator Description

Figure 3 Indicators on the outside of the S5735-S8P2X-IA200G1
Figure 4 Indicators inside the maintenance compartment of the S5735-S8P2X-IA200G1
Table 6 Description of indicators

No.

Indicator

Name

Color

Status

Description

1

PWR

Power indicator

-

Steady off

The switch is powered off.

Green

Steady on

The switch is powered on and can communicate with the built-in power module properly.

Yellow

Steady on

The switch is powered on but cannot communicate with the built-in power module properly.

2

SYS

System status indicator

-

Steady off

The system is not running.

Green

Fast blinking

The system is starting.

Green

Steady on

In the system startup preparation phase, the SYS indicator is steady green for no more than 30 seconds.

Green

Slow blinking

The system is running normally.

Red

Steady on

The system does not work normally after registration, or a temperature alarm has been generated.

3

ALM

Alarm indicator

-

Steady off

There is no AC input or power supply is normal.

Red

Steady on

The power supply to the switch is abnormal.

4

USB

USB-based deployment indicator

-

Steady off

  • No USB flash drive is connected to the switch.
  • The USB port is damaged.
  • The indicator is damaged.
  • The USB flash drive does not have any configuration file and cannot be used for deployment.
  • The switch has been upgraded using the USB flash drive and is restarting.

Green

Steady on

A USB-based deployment has been completed.

Green

Blinking

The system is reading data from a USB flash drive.

Yellow

Steady on

The switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.

Red

Blinking

An error has occurred when the system is executing the configuration file or reading data from the USB flash drive.

5

-

Service port indicator

Green

Steady off

The port is not connected or has been shut down.

Steady on

The port is connected.

Blinking

The port is sending or receiving data.

Yellow

Steady off

The port does not supply power to any PD.

Steady on

The port is supplying power to the connected PD.

Blinking

The PD connected to the port is not a standard PD or its power exceeds the maximum power or power threshold of the port.

6

-

ETH port indicator

-

Steady off

The ETH port is not connected.

Green

Steady on

The ETH port is connected.

Green

Blinking

The port is sending or receiving data.

Power Supply Configuration

The S5735-S8P2X-IA200G1 has a built-in power module and does not support pluggable power modules. The S5735-S8P2X-IA200G1 can be directly connected to an external 220 V AC power supply and provide power for external devices. Table 7 lists the power supply configurations of the S5735-S8P2X-IA200G1.

Table 7 Power supply configurations

Power Supply Mode

Available Power

PoE

160 W

Maximum number of PoE ports (fully loaded):

  • 802.3af (15.4 W per port): 8
  • 802.3at (30 W per port): 5

12 V DC

Five 12 V DC outputs provide a total of 72 W power. The maximum power of a single output is 72 W.

24 V AC

Two 24 V AC outputs provide a total of 72 W power. The maximum power of a single output is 72 W.

The total maximum output power of PoE power output, five 12 V DC outputs, and two 24 V AC outputs is 160 W.

Heat Dissipation

The S5735-S8P2X-IA200G1 has no fans and uses natural heat dissipation.

Technical Specifications

Table 8 lists technical specifications of the S5735-S8P2X-IA200G1.

Table 8 Technical specifications

Item

Description

Memory (RAM)

1 GB

Flash

512 MB in total. To view the available flash memory size, run the display version command.

Mean time between failures (MTBF)

57.28 years

Mean time to repair (MTTR)

2 hours

Availability

> 0.99999

Service port surge protection

±1.5 kV in differential mode, ±6 kV in common mode

Power supply surge protection

Surge current:
  • AC input: 20 kA
Surge:
  • AC input: ±6 kV in differential mode; ±6 kV in common mode
  • 12 V DC output: ±2 kV in differential mode; ±4 kV in common mode
  • 24 V AC output: ±2 kV in differential mode; ±6 kV in common mode

Dimensions (H x W x D)

550 mm x 300 mm x 135 mm (21.65 in. x 11.81 in. x 5.31 in.)

Weight (including packaging)

12.2 kg (26.9 lb)

Stack ports

Not supported

RTC

Not supported

RPS

Not supported

PoE

Supported

Rated voltage range

220 V AC to 240 V AC, 50/60 Hz

Maximum voltage range

176 V AC to 264 V AC, 45 Hz to 66 Hz

Maximum power consumption (100% throughput)

  • With no output power: 34 W
  • With output power: 209 W (device power consumption: 49 W; output power: 160 W)
Typical power consumption (30% of traffic load)
  • Tested according to ATIS standard
  • EEE enabled
  • No PoE power consumption

31 W

Operating temperature

-40°C to +75°C (-40°F to 167°F)
NOTE:

–25ºC to +75ºC (–13ºF to +167ºF): sunshade needed; 400 LFM air velocity (minimum); GPON optical modules not supported

–25ºC to +70ºC (–13ºF to +158ºF): sunshade needed; 200 LFM air velocity (minimum); GPON optical modules supported

–30ºC to +60ºC (–22ºF to +140ºF): sunshade needed; 40 LFM air velocity (minimum); GPON optical modules supported

–35ºC to +55ºC (–31ºF to +131ºF): sunshade needed; no requirement on the air velocity; GPON optical modules supported

–35ºC to +45ºC (–31ºF to +113ºF): 1120 W/m2 solar radiation (maximum); no requirement on the air velocity

–40ºC to –35ºC (–40ºF to –31ºF): At least four Ethernet electrical ports must be working.

When the altitude is 1800-4000 m (5906-13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).

Storage temperature

-40°C to +85°C (-40°F to +185°F)

IP rating

IP55

Noise under normal temperature (27°C, sound power)

Noise-free (no fans)

Relative humidity

5% to 95%, noncondensing

Operating altitude

0-4000 m (0-13123 ft.)

Product certification

  • EMC certification
  • Safety certification
  • Manufacturing certification

Part number

02312NTA-001

Copyright © Huawei Technologies Co., Ltd.