The system view is displayed.
An E-Trunk is created and the E-Trunk view is displayed, or the view of an existing E-Trunk is directly displayed.
The member devices in an E-Trunk must be configured with the same E-Trunk ID.
A maximum of 16 E-Trunks can be created on a device.
The E-Trunk priority is set.
The E-Trunk priority is used for master/backup negotiation between two devices. The device with a higher priority is the master. In priority comparisons, numerically lower values have higher priority.
If the two devices have the same priority, the device with a smaller system ID is the master.
By default, the E-Trunk priority of a member device is 100.