If there are a large number of VPLS PEs, you can use the HVPLS networking scheme to reduce the performance requirements on PEs.
Kompella VPLS uses BGP as the signaling. Configuring an RR can solve the problem of excessive connections caused by VPLS full connections. Therefore, the switch supports only Martini HVPLS.