The display alarm manual-clear command displays the alarms that are not reported repeatedly after being cleared.
After the mask manual-clear alarm command is executed to prevent manually cleared active alarms from being reported repeatedly and then the clear alarm active command or MIB table hwAlarmActiveTable is used to manually clear active alarms, you can run the display alarm manual-clear command to view the active alarms that are not reported repeatedly after being cleared.
# Display the alarms that are not reported repeatedly after being cleared.
<HUAWEI> display alarm manual-clear
A/B/C/D/E/F/G/H/I/J
A=Sequence, B=RootKindFlag(Independent|RootCause|nonRootCause)
C=Generating time, D=Clearing time
E=ID, F=Name, G=Level, H=State
I=Description information for locating(Para info, Reason info)
J=RootCause alarm sequence(Only for nonRootCause alarm)
2/Independent/2016-05-04 10:38:46-08:00/-/0xff14280c/hwEntityOffline/Major/Start/ OID 1
.3.6.1.4.1.2011.5.25.129.2.1.13 Physical entity changed to the offline state. (E
ntityPhysicalIndex=16842752, BaseTrapSeverity=5, BaseTrapProbableCause=69120, Ba
seTrapEventType=5, EntPhysicalContainedIn=16777216, EntPhysicalName="LPU slot 1"
, RelativeResource="", ReasonDescription="Because of get offline message, the en
tity of SLOT1 changed to offline state")
Item |
Description |
---|---|
A/B/C/D/E/F/G/H/I/J |
Alarm display format |
A=Sequence |
Alarm sequence number. |
B=RootKindFlag(Independent|RootCause|nonRootCause) |
Flag indicating a root-cause alarm or a non-root-cause alarm:
|
C=Generating time |
Time when an alarm is generated. |
D=Clearing time |
Time when an alarm is cleared. |
E=ID |
Alarm ID. |
F=Name |
Alarm name. |
G=Level |
Alarm severity. To set this parameter, run the alarm-name severity command. |
H=State |
Alarm status:
|
I=Description information for locating(Para info, Reason info) |
Alarm description. |
J=RootCause alarm sequence(Only for nonRootCause alarm) |