< Home

display alarm urgent

Function

Using the display alarm urgent command, you can view hardware alarms on the device.

Format

display alarm urgent [ slot slot-id | time interval ]

Parameters

Parameter

Description

Value

slot slot-id

Specifies a slot ID.

The value depends on the device configuration.

time interval

Displays hardware alarms generated in the last period of time. interval specifies the period.

The value is an integer that ranges from 1 to 10000, in minutes.

Views

All views

Default Level

1: Monitoring level

Usage Guidelines

You can use the command to view hardware alarms, including alarms about the abnormality of the temperature, the fan, and the chip.

If no parameter is specified, the command displays all the hardware alarms.

Example

# Display hardware alarms of the device.

<HUAWEI> display alarm urgent
 Alarm:                                                                                                                             
                                                                                                                                    
Alarm                    Slot      Date        Time(DST)     Location                                                               
---------------------------------------------------------------------------                                                         
Temp normal              1         2000/04/09  04:52:47      Slot 1                                                                 
Temp low                 1         2000/04/09  04:52:14      Slot 1                                                                 
Temp normal              1         2000/04/09  04:39:05      Slot 1                                                                 
Temp high                1         2000/04/09  04:37:23      Slot 1                                                                 
Temp normal              2         2000/04/10  07:13:16      Slot 2                                                                 
Temp high                2         2000/04/10  07:11:22      Slot 2   
Table 1 Description of the display alarm urgent command output

Item

Description

Alarm

Details about an alarm.
  • Fan pulled out: A fan module is removed.
  • Fan plugged in: A fan module is installed.
  • Fan abnormal: A fan module is not working properly.
  • Fan normal: A fan module is working properly.
  • Fan unmatched: A fan module does not match the device model.
  • Fan matched: A fan module matches the device model.
  • Power pulled out: A power module is removed.
  • Power plugged in: A power module is installed.
  • Power abnormal: A power module is not working properly.
  • Power normal: A power module is working properly.
  • PWR Input Vol Low: A power module is in an input power outage or undervoltage condition.
  • PWR Input Vol Low Resume: A power module recovers from an input power outage or undervoltage condition.
  • Built-in power Off: A built-in power module does not provide power.
  • Built-in power On: A built-in power module provides power normally.
  • Temp high: The temperature is too high.
  • Temp low: The temperature is too low.
  • Temp normal: The temperature returns to the normal range.
  • Temp chip abnormal: A temperature sensor is faulty.
  • Temp chip normal: A temperature sensor recovers from a failure.
  • storage abnormal: The storage utilization exceeded 85%.

Slot

Slot ID of the device where alarms are generated.

Date

Date when alarms are generated.

Time(DST)

Time when alarms are generated.

Location

Position where alarms are generated.