Parameter |
Description |
Value |
---|---|---|
slot slot-id |
Specifies a slot ID. |
The value depends on the device configuration. |
time interval |
Displays hardware alarms generated in the last period of time. interval specifies the period. |
The value is an integer that ranges from 1 to 10000, in minutes. |
You can use the command to view hardware alarms, including alarms about the abnormality of the temperature, the fan, and the chip.
If no parameter is specified, the command displays all the hardware alarms.
# Display hardware alarms of the device.
<HUAWEI> display alarm urgent
Alarm:
Alarm Slot Date Time(DST) Location
---------------------------------------------------------------------------
Temp normal 1 2000/04/09 04:52:47 Slot 1
Temp low 1 2000/04/09 04:52:14 Slot 1
Temp normal 1 2000/04/09 04:39:05 Slot 1
Temp high 1 2000/04/09 04:37:23 Slot 1
Temp normal 2 2000/04/10 07:13:16 Slot 2
Temp high 2 2000/04/10 07:11:22 Slot 2
Item |
Description |
---|---|
Alarm |
Details about an alarm.
|
Slot |
Slot ID of the device where alarms are generated. |
Date |
Date when alarms are generated. |
Time(DST) |
Time when alarms are generated. |
Location |
Position where alarms are generated. |