< Home

md

Function

Using the md command, you can specified the Maintenance Domain (MD) and Maintenance Association (MA) of the NQA test packet to be sent. This command takes effect only in the MAC Ping test instance.

Using the undo md command, you can remove the specified MD from the NQA test packet to be sent.

By default, no MD is specified.

Format

md md-name ma ma-name

undo md

Parameters

Parameter Description Value
md-name Specifies an MD. The value is a string of 1 to 43 case-sensitive characters without spaces.
ma-name Specifies an MA. The value is a string of 1 to 43 case-sensitive characters without spaces.

Views

NQA view

Default Level

2: Configuration level

Usage Guidelines

You can use this command to specify the MD and MA of an MAC Ping test instance. This command has the same effect as the operation of checking the connectivity fault in the MA view. Before running this command, you need to create an MD and MA, and set the test type to macping.

You cannot modify the MD and MA when the test instance is running. The total length of ma-name and md-name combination cannot be greater than 44 characters.

Example

# Set the test type of an NQA test instance to MAC Ping and specify the MD name to "mdcustome" and the MA name to "macustomer".

<HUAWEI> system-view
[HUAWEI] nqa test-instance user test
[HUAWEI-nqa-user-test] test-type macping
[HUAWEI-nqa-user-test] md mdcustomer ma macustomer
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.