DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid-67851

Trap Buffer Description

Physical entity failed. (BaseTrapSeverity=[BaseTrapSeverity], BaseTrapProbableCause=[67851], BaseTrapEventType=[BaseTrapEventType], EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalContainedIn=[EntContainedIn], EntPhysicalName=[EntPhysicalName], RelativeResource=[RelativeResource], ReasonDescription=A loop is formed between ICU(s), either because two connections are established between ICUs or two ports of the same ICU are interconnected.)

The control channel between physical entities is faulty.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Alert

Mnemonic Code

hwEntityInvalid_S

Trap OID

1.3.6.1.4.1.2011.5.25.129.2.1.9

MIB

HUAWEI-BASE-TRAP-MIB

Alarm ID

0x08130055

Alarm Name

hwEntityInvalid

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.129.2.1.10 hwEntityResume-67851

Trap Buffer Parameters

Parameter Description

BaseTrapSeverity

To describe the level of trap.

ProbableCause

To describe the probable cause of trap.

BaseTrapEventType

To describe the type of trap.

EntityPhysicalIndex

The index of the physical entity.

EntContainedIn

The value of entPhysicalIndex for the physical entity which 'contains' this physical entity.

EntPhysicalName

The textual name of the physical entity.

RelativeResource

This object may contain a key word to indicate the relative resource of an entity.

ReasonDescription

To describe the reason of trap in DisplayString style.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.129.1.1

hwBaseTrapSeverity

-

1.3.6.1.4.1.2011.5.25.129.1.2

hwBaseTrapProbableCause

-

1.3.6.1.4.1.2011.5.25.129.1.3

hwBaseTrapEventType

-

1.3.6.1.2.1.47.1.1.1.1.4

entPhysicalContainedIn

entPhysicalIndex

1.3.6.1.2.1.47.1.1.1.1.7

entPhysicalName

entPhysicalIndex

1.3.6.1.4.1.2011.5.25.129.1.4

hwBaseTrapRelativeResource

-

1.3.6.1.4.1.2011.5.25.129.1.5

hwBaseTrapReasonDescr

-

Impact on the System

1. If dual MPUs are used, no services are affected but reliability is degraded.

2. If a single MPU is deployed, the entire chassis is restarted and all services on the chassis are interrupted.

Possible Causes

A loop is formed between ICU(s), either because two connections are established between ICUs or two ports of the same ICU are interconnected.

Procedure

1. View the EntPhysicalName field in alarm information. Check which two interfaces form a ring.

2. Remove the cables of the corresponding interfaces. Note that the alarm generated when the device is started with a ring will not be cleared after the ring is broken. You must run a command to clear the alarm or restart the device.

3. Connect the cables as specified.

Copyright © Huawei Technologies Co., Ltd.