DEVM_1.3.6.1.4.1.2011.5.25.41.4.8 hwIfMonitorOutputRateResume

Trap Buffer Description

Interface output flow bandwidth usage resumed below the trap threshold.(Interface=[IfIndex], BandWidthUsage=[hwSubifOutputRatePercentage], TrapThreshold=[hwSubifOutputRateThreshold], InterfaceName=[InterfaceName])

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwSubifOutputRateRising

Trap OID

1.3.6.1.4.1.2011.5.25.41.4.8

MIB

HUAWEI-IF-EXT-MIB

Alarm ID

0x081300af

Alarm Name

hwIfMonitorOutputRateRising

Alarm Type

processingErrorAlarm

Raise or Clear

Clear

Match trap

DEVM_1.3.6.1.4.1.2011.5.25.41.4.7 hwIfMonitorOutputRateRising

Trap Buffer Parameters

Parameter Description

IfIndex

Interface index.

hwSubifOutputRatePercentage

Output flow bandwidth usage.

hwSubifOutputRateThreshold

Trap threshold.

InterfaceName

Interface name.

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.10

hwIfMonitorOutputRate

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.11

hwIfMonitorOutputRateThreshold

hwIfMonitorIndex

1.3.6.1.4.1.2011.5.25.41.1.7.1.1.19

hwIfMonitorName

hwIfMonitorIndex

Impact on the System

Services are not affected.

Possible Causes

The interface traffic statistics collection period can be configured. The default value is 300s. The average rate of the previous statistics collection period is calculated in every 1/6 of the statistics collection period and then divided by the interface bandwidth to obtain the interface bandwidth usage. If the interface bandwidth usage falls below the interface alarm threshold, the interface rate threshold-crossing alarm is cleared.

Procedure

This trap message is informational only, and no action is required. None