The card failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityType=[EntityType], EntityTrapFaultID=135197, Reason=A voltage drop occurred on the board.)
The subcard experienced a partial failure.
In VS mode, this trap is supported only by the admin VS.
Trap Attribute | Description |
---|---|
Alarm or Event |
Alarm |
Trap Severity |
Alert |
Mnemonic Code |
hwCardFail |
Trap OID |
1.3.6.1.4.1.2011.5.25.219.2.3.3 |
MIB |
HUAWEI-ENTITY-TRAP-MIB |
Alarm ID |
0x08130056 |
Alarm Name |
hwCardFail |
Alarm Type |
equipmentAlarm |
Raise or Clear |
Raise |
Match trap |
Parameter | Description |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntityTrapFaultID |
Indicates the error code. |
EntPhysicalName |
Indicates the name of the physical entity. |
EntityType |
Indicates the type of the physical entity. |
Reason |
Indicates the description of the cause of the trap. |
VB OID | VB Name | VB Index |
---|---|---|
1.3.6.1.4.1.2011.5.25.219.1.1 |
hwEntityPhysicalIndex |
- |
1.3.6.1.2.1.47.1.1.1.1.7 |
entPhysicalName |
entPhysicalIndex |
1.3.6.1.4.1.2011.5.25.219.1.2 |
hwEntityTrapEntType |
- |
1.3.6.1.4.1.2011.5.25.219.1.3 |
hwEntityTrapFaultID |
- |
1.3.6.1.4.1.2011.5.25.219.1.13 |
hwEntityTrapReasonDescr |
- |
1.3.6.1.4.1.2011.5.25.31.1.1.1.1.2 |
hwEntityOperStatus |
entPhysicalIndex |
1. Check whether external power supply is normal.If a power supply problem exists, locate and resolve the problem.
2. Remove the associated board and insert it again. Check whether the board can successfully register. If the registration fails, replace the board.