PTP_1.3.6.1.4.1.2011.5.25.187.5.11 hwPTPRingFiberLengthChange

Trap Buffer Description

The optical fiber length of the ring-network is changed. (hwPtpPortName=[hwPtpPortName], hwPtpPortIfIndex=[hwPtpPortIfIndex], hwPtpPortRingFiberLengthChangeValue=[hwPtpPortRingFiberLengthChangeValue], hwPtpPortRingFiberLengthChangeValueFlag=[hwPtpPortRingFiberLengthChangeValueFlag])

The length of the optical fiber on the ring network is changed.

In VS mode, this trap is supported only by the admin VS.

Trap Attributes

Trap Attribute Description

Alarm or Event

Alarm

Trap Severity

Warning

Mnemonic Code

hwPTPRingFiberLengthChange

Trap OID

1.3.6.1.4.1.2011.5.25.187.5.11

MIB

HUAWEI-PTP-MIB

Alarm ID

0x09af000a

Alarm Name

hwPTPRingFiberLengthChange

Alarm Type

equipmentAlarm

Raise or Clear

Raise

Match trap

PTP_1.3.6.1.4.1.2011.5.25.187.5.12 hwPTPRingFiberLengthChangeResume

Trap Buffer Parameters

Parameter Description

hwPtpPortName

Indicates the name of the current port.

hwPtpPortIfIndex

Interface index

hwPtpPortRingFiberLengthChangeValue

Indicates the new time offset caused by the fiber length change of the current port. The new time offset is the sum of the currently configured fiber asymmetry compensation value. (unit: ns)

hwPtpPortRingFiberLengthChangeValueFlag

Indicates the plus or minus sign of the new time offset caused by the fiber change of the current port.

The options are as follows:

Negative sign (0)

Positive sign (1)

VB Parameters

VB OID VB Name VB Index

1.3.6.1.4.1.2011.5.25.187.2.1.1.43

hwPtpPortName

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.45

hwPtpPortRingFiberLengthChangeValue

hwPtpPortIfIndex

1.3.6.1.4.1.2011.5.25.187.2.1.1.46

hwPtpPortRingFiberLengthChangeValueFlag

hwPtpPortIfIndex

Impact on the System

The precision of clock synchronization is affected.

Possible Causes

The difference between the time offset caused by the fiber length change and the set asymmetric correction value exceeded the acceptable range (from - 200 ns to + 200 ns).

Procedure

1. Run the display this command in the interface view to check whether the asymmetric correction value is configured on the interface.

  • If yes, go to Step 2.
  • If no, go to step 3.

2. Run the ptp asymmetry-correction { positive correction-value | negative correction-value } command to reconfigure the asymmetric correction value. If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact Huawei technical support personnel.

4. End.