te bandwidth (Interface view) (IETF)

Function

The te bandwidth command sets or modifies the bandwidth of a BC.

By default, no BC bandwidth is configured for a link.

Format

te bandwidth { bc0 bc0Bw | bc1 bc1Bw | bc2 bc2Bw | bc3 bc3Bw | bc4 bc4Bw | bc5 bc5Bw | bc6 bc6Bw | bc7 bc7Bw } *

Parameters

Parameter Description Value
bc0 bc0Bw

Specifies the bandwidth of BC0.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc1 bc1Bw

Specifies the bandwidth of BC1.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc2 bc2Bw

Specifies the bandwidth of BC2.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc3 bc3Bw

Specifies the bandwidth of BC3.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc4 bc4Bw

Specifies the bandwidth of BC4.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc5 bc5Bw

Specifies the bandwidth of BC5.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc6 bc6Bw

Specifies the bandwidth of BC6.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

bc7 bc7Bw

Specifies the bandwidth of BC7.

The value is an integer ranging from 0 to 4000000000, in kbit/s.

Views

100ge sub-interface view, 100GE interface view, 10GE sub-interface view, 10GE interface view, 25GE sub-interface view, 25GE interface view, 400GE sub-interface view, 400GE interface view, 40GE sub-interface view, 40GE interface view, 50GE sub-interface view, 50GE interface view, Eth-Trunk sub-interface view, Eth-Trunk interface view, GE optical interface view, GE sub-interface view, GE electrical interface view, GMPLS-UNI interface view, Tunnel interface view, XGE sub-interface view, XGE interface view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
mpls-te write

Usage Guidelines

Usage Scenario

In real-world situations, the command needs to be run only on the outbound interface of a link through which a TE tunnel passes.

If the command is run more than once, the latest configuration overrides the previous one.

Precautions

MPLS TE-related commands apply only to MPLS TE and SR-MPLS TE. However, this command applies to SRv6 TE Policies, besides MPLS TE and SR-MPLS TE.

Example

# Set the bandwidth of BC0 to 1000 kbit/s.
<HUAWEI> system-view
[~HUAWEI] te attribute enable
[*HUAWEI] interface GigabitEthernet 0/1/0
[*HUAWEI-GigabitEthernet0/1/0] te bandwidth max-reservable-bandwidth 100000
[*HUAWEI-GigabitEthernet0/1/0] te bandwidth bc0 1000
Copyright © Huawei Technologies Co., Ltd.