Function

The binding interface time-slot command binds timeslots or sub-timeslots to a flexible Ethernet (FlexE) Client. The bound timeslots constitute bandwidth of the FlexE client.

The undo binding interface time-slot command unbinds timeslots or sub-timeslots from a FlexE client.

By default, no timeslot is bound to a FlexE client, that is, the default bandwidth is 0.

This command is supported only on the NetEngine 8000 F2A.

Format

binding interface { ifname | iftype ifnum } time-slot timeslot-list [ sub-time-slot subtimeslots ]

undo binding interface { ifname | iftype ifnum } [ time-slot timeslot-list [ sub-time-slot subtimeslots ] ]

Parameters

Parameter Description Value
iftype

Specifies an interface type.

The value is a string of 1 to 32 characters.

ifnum

Specifies an interface number.

The value is a string of 1 to 32 characters.

time-slot timeslot-list

Specifies a list of timeslots with the 5 Gbit/s granularity to be bound.

The value is a string of 1 to 199 case-sensitive characters, spaces not supported.

sub-time-slot subtimeslots

Specifies a list of sub-timeslots.

The value is a string of 1 to 9 characters. A timeslot list is continuous, consecutive, or hybrid. A continuous timeslot list uses an en dash (?). For example, 1-3 indicates sub-timeslots 1 to 3. A consecutive timeslot list uses a comma (,) for separation. For example, 1, 3. A hybrid list uses both symbols. For example, 1-2, 4.

Views

FlexE Client View

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
device-mgr write

Usage Guidelines

Usage Scenario

To bind one or more 5 Gbit/s timeslots of a physical interface in FlexE mode in a FlexE group or one or more sub-timeslots in a 5 Gbit/s timeslot to a FlexE client, run the binding interface time-slot command. The bound timeslots or sub-timeslots constitute bandwidth of the FlexE client.

Prerequisites

A physical interface in FlexE mode has been added to a FlexE group using the binding interface command.

To bind sub-timeslots with the 1 Gbit/s granularity, ensure that the sub-timeslot granularity has been set to 1 Gbit/s using the set flexe sub-time-slot granula command.

Precautions

In VS mode, this command is supported only by the admin VS.

Example

# Bind timeslot 1 to the FlexE Client 1.
<HUAWEI> system-view
[~HUAWEI] flexe client-instance 1
[~HUAWEI-flexe-client-1] binding interface FlexE-50G 0/1/52 time-slot 1
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.