emdi bier bind lpu-group

Function

The emdi bier bind lpu-group command is used to bind a lpu group of bier.

The undo emdi bier bind lpu-group command cancels the binding relationship of bier.

By default, EMDI BIER not bind lpu group.

This command is supported only on the NetEngine 8000 F1A.

Format

emdi bier bind lpu-group lpu-group-name

undo emdi bier bind lpu-group lpu-group-name

Parameters

Parameter Description Value
lpu-group-name

Specifies the name of an EMDI lpu group.

The name is a string of 1 to 31 case-sensitive characters, spaces not supported.

Views

EMDI view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
emdi write

Usage Guidelines

Usage Scenario

When the EMDI BIER detection solution is used, after the EMDI boards to be detected are configured, run the emdi bier bind lpu-group command to bind a lpu group of bier to detect indicators of bier channels.

Prerequisites

A board group has been created using the emdi lpu-group command. It is recommended that the emdi bind slot all command be configured on the P node to bind all lpu groups.

Precautions

  • Only one EMDI lpu group can be bound in bier.
  • The emdi bier bind lpu-group command is not supported in multi-VS scenarios. To make BIER EMDI take effect in multi-VS scenarios, configure the emdi lpu-group and emdi bier bind lpu-group commands in Admin-VS.
  • When the number of BIER channels exceeds 90% of the upper limit, a threshold alarm is reported. When the number of BIER channels reaches the upper limit, an upper limit-crossing alarm is reported. When the upper limit-crossing alarm is reported, the threshold alarm is cleared. When the number of BIER channels falls below the upper limit, the upper limit-crossing alarm is cleared. When the number of BIER channels falls below 80% of the upper limit, the threshold alarm is cleared. When the number of BIER channels falls below between 80% and 90% of the upper limit, the threshold alarm remains unchanged. When both the common EMDI and BIER EMDI are configured, a threshold alarm may be triggered when the number of channels reaches the upper limit. If the threshold alarm is triggered, it will be cleared in about 2 minutes, leaving only the upper limit-crossing alarm.

Example

# Bind EMDI lpu group 1 in bier.
<HUAWEI> system-view
[~HUAWEI] emdi
[~HUAWEI-emdi] emdi bier bind lpu-group 1
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.
< Previous topic Next topic >