loop-detect trigger enable

Function

The loop-detect trigger enable command enables proactive loop detection upon an interface Up state.

The undo loop-detect trigger enable command disables proactive loop detection upon an interface Up state.

By default, proactive loop detection upon interface Up is disabled.

Format

loop-detect trigger enable

undo loop-detect trigger enable

Parameters

None

Views

System view

Default Level

2: Configuration level

Task Name and Operations

Task Name Operations
vlan write

Usage Guidelines

Usage Scenario

To enable or disable the proactive loop detection upon interface Up function globally, run the loop-detect trigger enable command.

After this function is enabled, loop detection is triggered when an interface is bound to a VSI or a physical interface changes from Down to Up. If a loop is detected on a sub-interface of the physical interface, this physical interface is blocked.

You can run the reset loop-detect trigger trigger-down command or run the shutdown and undo shutdown commands in sequence to unblock the interface.

Precautions

Proactive loop detection fails to take effect on interfaces that have STP, local loopback, loop detection, or loopback detection enabled.

It is recommended that you disable this function on properly running devices. If you have to use this function to detect whether links operate properly during site deployment, be sure to disable this function after this stage.

Example

# Enable proactive loop detection upon interface Up in the system view.
<HUAWEI> system-view
[~HUAWEI] loop-detect trigger enable
Copyright © Huawei Technologies Co., Ltd.
Copyright © Huawei Technologies Co., Ltd.