reverse mode

Function

The reverse mode auto-resume command sets the alarm inversion mode to automatic recovery.

The undo reverse interface command deletes the alarm reversion mode.

By default, the alarm reversion mode is not configured on an interface.

Format

reverse mode auto-resume

undo reverse mode

Parameters

None

Views

Alarm management view

Default Level

3: Management level

Task Name and Operations

Task Name Operations
fault-mgr write

Usage Guidelines

Usage Scenario

After the reverse mode auto-resume command has been run to set the alarm inversion mode of global alarms to automatic recovery, run the reverse interface command in the interface view to configure alarm inversion on an interface.

Configuration Impact

After the reverse mode auto-resume command has been run to set the alarm inversion mode of global alarms to automatic recovery, the system checks key alarms on the interface that has alarm inversion configured. If no key alarm exists, the system automatically deletes the alarm inversion configuration.

Follow-up Procedure

Run the reverse interface command to configure alarm inversion on an interface.

Example

# Set the alarm inversion mode to automatic recovery.
<HUAWEI> system-view
[~HUAWEI] alarm
[~HUAWEI-alarm] reverse mode auto-resume
Copyright © Huawei Technologies Co., Ltd.