BRASAM/6/AMV6_LOG_ISOLATE_PREFIX_RECOVER

Message

BRASAM/6/AMV6_LOG_ISOLATE_PREFIX_RECOVER: The device triggers a switchover when the prefix pool has been isolated for 20 times. (PrefixName=[PrefixName])

This log is supported only on NetEngine 8000 F1A.

In VS mode, this log is supported only by the admin VS.

Description

The device triggers a switchover when the prefix pool has been isolated for 20 times.

Parameters

Parameter Name Parameter Meaning

PrefixName

Name of a prefix pool.

Possible Causes

The device triggers a switchover when the prefix pool has been isolated for 20 times.

Procedure

1. Run the display ipv6 prefix name command to check the number of times that the address pool is isolated.

2. Run the clear auto-block ipv6-prefix command in the diagnostic view to unlock the address pool.

  • If the fault persists, go to Step 3.
  • If the fault is rectified, go to Step 4.

3. Collect alarm, log, and configuration information, and contact technical support personnel.

4. End.