DRIVER/2/CLOADPICLOGICFAIL

Message

DRIVER/2/CLOADPICLOGICFAIL: [CardType][CardID]: FPGA Load Fail ([Reason]).

Description

The subcard logic failed to be loaded, and related information was displayed.

Parameters

Parameter Name Parameter Meaning

CardType

Subcard type.

CardID

Subcard ID.

Reason

Cause of the fault.

Possible Causes

Cause 1: The FPIC was not properly installed.

Cause 2: The subcard was faulty.

Cause 3: The backplane was faulty.

Procedure

1. Check whether the subcard is installed on an FPIC.

  • If so, go to Step 2.
  • If not, go to Step 5.

2. Check whether the motherboard of the faulty subcard is reset.

  • If yes, go to Step 10.
  • If not, go to Step 3.

3. Power off the faulty subcard and then power it on.

  • If the fault is rectified, go to Step 10.
  • If the fault persists, go to Step 4.

4. Remove and insert the faulty subcard.

  • If the fault is rectified, go to Step 10.
  • If the fault persists, go to Step 5.

5. Check whether the motherboard of the faulty subcard is a subcard.

  • If so, go to Step 6.
  • If not, go to Step 9.

6. Power off and then power on the board.

a. For non-FPICs:

  • If the fault is rectified, go to Step 10.
  • If the board cannot be registered, go to Step 8.

b. For FPICs:

  • If the fault is rectified, go to Step 10.
  • If the board cannot be registered or the alarm cannot be cleared after the board is registered, go to Step 7.

7. Replace the subcard.

  • If the fault is rectified, go to Step 10.
  • If the fault persists, go to Step 8.

8. Replace the board.

  • If the fault is rectified, go to Step 10.
  • If the fault persists, go to Step 9.

9. Collect alarm, log, and configuration information and contact Huawei technical support engineers.

10. End.