DEVM/1/hwChassisFail_active: The chassis resumed from partial failure. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131351, Reason=Power backplane cable is not stable.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity, such as chassis. |
EntityTrapFaultID |
Indicates the error code. |
ReasonDescription |
Indicates the description of the cause of the trap. |
1. Run the slave switchover command to switchover ,and wait for a period of time,check whether the alarm is cleared.
2. Contact technical support and check whether the power supply unit backplane cable is securely inserted.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.