DEVM/1/hwChassisFail_active: The chassis resumed from partial failure. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131352, Reason=The cable of LPU area is not stable.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity, such as chassis. |
EntityTrapFaultID |
Indicates the error code. |
ReasonDescription |
Indicates the description of the cause of the trap. |
1. Remove and then insert the faulty fan located in the LPU area.When the fan is registered, check whether the alarm is cleared.
2. Contact technical support personnel. and check whether the LPU area cable for the fan backplane is securely inserted.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.