DEVM/1/hwChassisFail_active-131352

Message

DEVM/1/hwChassisFail_active: The chassis resumed from partial failure. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131352, Reason=The cable of LPU area is not stable.)

This log is supported only on NetEngine 8000 F1A.

In VS mode, this log is supported only by the admin VS.

Description

The chassis experienced a partial failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalIndex

Indicates the index of the physical entity.

EntPhysicalName

Indicates the name of the physical entity, such as chassis.

EntityTrapFaultID

Indicates the error code.

ReasonDescription

Indicates the description of the cause of the trap.

Possible Causes

Fan backplane cable of LPU area is not stable

Procedure

1. Remove and then insert the faulty fan located in the LPU area.When the fan is registered, check whether the alarm is cleared.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 2.

2. Contact technical support personnel. and check whether the LPU area cable for the fan backplane is securely inserted.

  • If the alarm is cleared, go to Step 4.
  • If the alarm persists, go to Step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.