DEVM/1/hwChassisFail_active: The chassis failed partially. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=131353, Reason=The cable of SFU area is not stable.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalIndex |
Indicates the index of the physical entity. |
EntPhysicalName |
Indicates the name of the physical entity, such as chassis. |
EntityTrapFaultID |
Indicates the error code. |
ReasonDescription |
Indicates the description of the cause of the trap. |
If this alarm occurs, the fans in the SFU area cannot work properly.
1. Remove and then insert the faulty fan located in the SFU area.When the fan is registered, check whether the alarm is cleared.
2. Contact technical support personnel. and check whether the SFU area cable for the fan backplane is securely inserted.
3. Collect trap, log, and configuration information, and contact technical support.
4. End.