DEVM/2/hwCommunicateError_active: The communication channel failed. (EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapEntType=[EntityTrapEntType], EntityTrapFaultID=140304, EntityCommunicateType=[EntityCommunicateType], Reason=The I2C control bus on the backplane malfunctions.)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
EntityPhysicalIndex |
The index for this entry. |
EntPhysicalIndex |
The index for this entry. |
EntPhysicalName |
The textual name of the physical entity. |
EntityTrapEntType |
The type of this entity. |
EntityTrapFaultID |
To describe the fault id of trap. |
EntityCommunicateType |
The type of this commnuicate. The value can be: 1. Control channel:1. 2. monitor channel:2. 3. clock channel:3. 4. data channel:4. |
Reason |
Reason integer. |
1. Replace the involved subcard in the coprresponding slot.
2. If the fault persists, replace the main control board in the slot.
3. If the fault persists, replace the chassis.
4. Collect the information about alarms, logs, and configurations, and then contact Huawei technical support personnel.
5. End.