DEVM/1/hwEntityRemove_active: Physical entity is removed.(BaseTrapSeverity=3, BaseTrapProbableCause=65540, BaseTrapEventType=5, EntityPhysicalIndex=[ULONG], EntPhysicalContainedIn=[ULONG], EntPhysicalName=[STRING], Reason=Chassis <chassisID> is removed)
In VS mode, this log is supported only by the admin VS.
Parameter Name | Parameter Meaning |
---|---|
BaseTrapSeverity |
Indicates the severity level of the trap reported to the NMS. |
BaseTrapProbableCause |
Indicates the possible cause of the trap. |
BaseTrapEventType |
Indicates the trap type. |
EntityPhysicalIndex |
Indicates the physical index. |
EntPhysicalContainedIn |
Indicates the parent index. |
EntPhysicalName |
Indicates the name of the entity such as a chassis. |
Reason |
Reason. |
1. Locate the chassis in which the trap is generated.
2. Check whether the link between the master CCC and the slave CCC is normal.
3. Check whether the two MPUs in the slave CCC work normally. Run the display device command to check whether the MPUs are present.
4. Replace the cable between the master CCC and the slave CCC and then check whether the trap is cleared.
5. Replace the faulty MPU and then check whether the trap is cleared.
6. Check whether the cable between the CLC and the CCC is correctly connected.
7. Replace the faulty cable between the CCC and the CLC and then check whether the trap is cleared.
8. Check whether the MPU in the CLC is working properly.
9. Collect the trap information, log information, and configuration information, and contact technical support personnel.
10. End.