DEVM/1/hwPowerFail_active-136714

Message

DEVM/1/hwPowerFail_active: A power module experienced a partial failure.(EntityPhysicalIndex=[EntityPhysicalIndex], EntPhysicalIndex=[EntPhysicalIndex], EntPhysicalName=[EntPhysicalName], EntityTrapFaultID=136714, Reason=The current of the power is not average.)

In VS mode, this log is supported only by the admin VS.

Description

The power supply experienced a partial failure, which may be caused by a component failure.

Parameters

Parameter Name Parameter Meaning

EntityPhysicalIndex

The index for this entry.

EntPhysicalIndex

The index for this entry.

EntPhysicalName

The textual name of the physical entity.

EntityTrapFaultID

To describe the fault id of trap.

Reason

Reason.

Possible Causes

The current of the power is not average.

Procedure

1. If the faulty PM module is newly inserted, check whether it is properly inserted, the backplane has bent pins, or its connector has faults.

  • If any of the preceding faults occurs, go to Step 2.
  • If none of the preceding faults occurs, go to Step 3.

2. Execute the operations according to the following conditions.

  • If the PM module is not properly inserted, insert it properly.
  • If the backplane has bent pins, do not insert the PM module to the fault slot. In this case, contact technical support personnel.
  • If the PM module connector is faulty, replace the PM module.
  • If the faulty power module is not newly inserted, go to step 3.

3. Collect trap, log, and configuration information, and contact technical support.

4. End.